Page 7 - RayOne EMV Platform Brochure 2024_2.2
P. 7

5     RAYONE EMV
              & EMV TORIC





         RayOne EMV & EMV Toric






















          KEY INFORMATION


          •  Up to 1.5 D increased
           range of focus with an
           emmetropic target. 1,4,6
          •  High levels of contrast
           sensitivity  and low levels of                                                         ENHANCED
                    1
                                                                                                    TORIC
           dysphotopsia , similar to                                                              MARKINGS
                      2,5
           standard monofocal lenses.
          •  Positive spherical aberration
           design provides a natural
           range of vision. 2,4
                                        Centre region: Induced              CORRECT MORE OF YOUR PATIENTS,
                                        positive spherical aberration       EVEN THOSE WITH SIGNIFICANT
          DESIGNED TO PROVIDE:
                                                                            CORNEAL ASTIGMATISM
          •  Smoother, blended
           transition between the                                           •  Proven rotational stability and
           eyes when compared to                                             centration with predictable,
                                                                                      8
           monovision with standard                                          sustainable and accurate
           monofocals, maintaining                                           visual results
           binocular stereoacuity and
           reducing asthenopia.                                             •  Average offset of only 0.08 mm
                                                                             3 to 6 months after surgery 8
          •  High quality spectacle-free
           distance vision.                                                 •  1.83° mean IOL rotation 3 to 6 months
                                                                             after surgery 8
          •  Reduced pupil dependency,
           for optimised performance                                        •  Available in a wide range of IOL
           under low light conditions.                                       plane cylinders: +0.75 D to +4.5 D,
                                                                             in +0.75 D increments
          •  Reduced sensitivity to
           decentration and tilt
           compared to other
           IOL designs.
                                        Blended edge region: Reduced
          •  Complements the
                                        longitudinal spherical
           eye’s natural level of       aberration designed to
           spherical aberration.        maintain visual acuity and
                                        contrast sensitivity under
          •  Fully preloaded across     mesopic conditions
           the entire power range.
   2   3   4   5   6   7   8   9   10   11   12