3     CLINICAL
              RESULTS


         Clinical results with RayOne EMV






          Since the launch of RayOne EMV in 2020, clinical data from across Europe has demonstrated that: 1,2,3,6,7
            • RayOne EMV can provide spectacle independence in the distance to intermediate vision.
          • RayOne EMV provides improvement in intermediate vision without compromising the binocular distance vision.
          • RayOne EMV can help to improve your patients’ near vision, particularly when used with monovision.


          The following clinical results are from patients in the UK, Spain and Portugal during the months leading up to the
          commercial launch of RayOne EMV. 2


                      Value                               Acuity @ 1 month (LogMAR)   Snellen Approximation
           MONOVISION
                      Binocular UDVA               (n=18)  -0.03 ± 0.05             6/6    20/20
                      Dominant Eye UDVA            (n=18)  -0.02 ± 0.07             6/6    20/20
                      Binocular UIVA               (n=17)  0.08 ± 0.12              N8 @ 100 cm     J1 / J2 @ 40 cm
                      Binocular UNVA                (n=5)  N6   Range, N4 – N10     6/9   20/32







               70%                        100%                       100%                      100%



            of patients reported    of patients reported no     of patients reported no     of patients reported
         spectacle independence at   difficulty negotiating steps,   incidence of halo, glare,   being dysphotopsia free
           distance, intermediate    stairs or curbs with no depth   starbursts or haze
                 and near            perception or contrast
                                   sensitivity issues reported




                     Dr. Mariano Royo, Director of Ophthalmology at the Hospital San Rafael in Madrid, shared his clinical results
                     of 22 eyes of 11 patients implanted with RayOne EMV at six months post-op and 70 eyes of 35 patients
           EMMETROPIA
                     implanted with TECNIS Eyhance (Johnson & Johnson Vision). Bilateral emmetropia was targeted for all
                     patientsin both groups. The defocus curve below reports the binocular vision obtained using the best
                                RayOne EMV - TECNIS Eyhance
                     distance correction. 6
              1.20                                                                   -0.08       RayOne EMV patients
                                                                                                 reporting spectacle
              1.00                                       ~50cm   ~33cm                0.00         independence:
            Visual Acuity (Decimal)  0.60                                             0.22  Visual Acuity (logMAR)  distance &
              0.80
                                                                                      0.10
                                                                                                     100%

              0.40
                                                                                      0.40
              0.20
                                                                                      0.70       intermediate vision
              0.00
                 3.00    2.00    1.00    0.00    -1.00  -2.00   -3.00   -4.00   -5.00  1.30              33%
                                     Defocus Level (Dioptres)

                                        RayOne EMV           TECNIS Eyhance                      functional near vision
   1   2   3   4   5   6   7   8   9   10